Sigenergy - Sigen Hybrid Inverter 110kW
Sigenergy - Sigen Hybrid Inverter 110kW
Reliable, Efficient & Battery-Ready Hybrid Power Solution . Learn more about Sigenergy
Key Features - Sigenergy Sigen Hybrid Inverter 110kW:
- Ideal for commercial solar setups.
- Battery-Ready – Seamlessly integrates with SigenStack BAT 12.0 for energy storage (supports 4–21 modules).
- Flexible & Scalable – Supports parallel operation without a data logger.
- Safety First – AFCI, DC reverse polarity, residual current monitoring, and more.
- Outdoor-Proof – IP66 protection and smart air cooling for all-weather reliability.
- Efficient – Up to 98.6% max efficiency at 400V and 98.8% at 480V.
Technical Specifications - Sigenergy Hybrid Inverter:
PV Input (DC):
- Max. PV Input Power: 220,000 Wp
- Max. DC Input Voltage: 1,100 V
- Nominal DC Input Voltage: 600V @380/400 Vac, 720V @480 Vac
- Start-up Voltage: 180 V
- MPPT Voltage Range: 160 – 1,000 V
- Number of MPPTs: 8
- PV Strings per MPPT: 2
- Max. Input Current per MPPT: 32 A
- Max. Short-Circuit Current per MPPT: 50 A
Battery Input (DC):
- Compatible Battery Model: SigenStack BAT 12.0
- Battery Module Range: 4 – 21 modules
- Max. Charge Power: 110,000 W
- Max. Discharge Power: 110,000 W
- Max. Operating Current: 180 A
AC Output:
- Nominal Active Power: 110,000 W
- Max. Apparent Power: 110,000 VA
- Max. Output Power (cosΦ = 1): 110,000 W
- Nominal Output Voltage: 400/480V, 3W+(N)+PE
- Nominal Output Current:
- 159.4 A @400Vac
- 132.4 A @480Vac
- Max. Output Current:
- 159.4 A @400Vac
- 132.4 A @480Vac
- Nominal Grid Frequency: 50 / 60 Hz
- Power Factor: 0.8 leading to 0.8 lagging
- THDi: < 3%
Efficiency:
- Max. Efficiency: 98.6% @400V, 98.8% @480V
- European Efficiency: 98.4% @400V, 98.6% @480V
General Specifications Sigen Inverter Hybrid:
- Dimensions: 918 × 640 × 340 mm
- Weight: 78 kg
- Nighttime Power Consumption: < 3.5 W
- Operating Temperature Range: -30°C to 60°C
- Storage Temperature Range: -40°C to 70°C
- Relative Humidity Range: 0% – 100%
- Max. Operating Altitude: 5,000 m (derating applies above 4,000 m)
- Cooling System: Smart air cooling
- Ingress Protection Rating: IP66
- PV Connection Type: MC4 (Max. 6 mm²)
- AC Connection Type: OT / DT terminal (Max. 240 mm²)
- Communication Options: WLAN, Fast Ethernet, RS485, Sigen CommMod (4G/3G/2G)
Built-in Protections Sigenergy Hybrid Inverters:
- DC reverse polarity
- Insulation monitoring
- Residual current monitoring
- Arc fault circuit interrupter (AFCI)
- AC overcurrent, overvoltage, short-circuit protection
- Type II DC/AC surge protection
- Anti-islanding protection