Expanded Power Options for Single-Phase SigenStor Installations

Sigenergy has recently expanded its gateway portfolio to cater to a wider range of installation requirements. This article provides an overview of the new Sigen Energy Gateway HomePro SP-F gateway and explains how it fits within the current range of gateway options available in Australia.

Sigen gateways are a key component of SigenStor energy storage systems and are essential when the system is required to provide backup power during a grid outage.

Introducing the HomePro SP-F Gateway

The new HomePro SP-F gateway is a single-phase device that provides similar functionality to the existing HomePro SP gateway, but with a significantly higher AC power rating. The HomePro SP-F gateway has a 100A (22kW) grid connection rating and can deliver this full level of power to the backup port, supporting up to 22kW of backup load during a grid outage.

The smart port / generator connection is also rated at 22kW, making the SP-F a strong fit for larger single-phase installations where higher backup capacity is required without moving to a three-phase system.

The HomePro SP-F gateway is designed to connect to up to 22kW of inverter capacity. There are three inverter input circuit breakers provided (two 63A breakers and one 40A) however Australian Standards limit the number of inverters able to be connected directly to the gateway to two.

Sigenergy Gateway Range Comparison

The table below compares the current Sigenergy Gateway range for the Australian market as of July 2026.

Feature

Sigen Gateway Home SP AU

Sigen Gateway HomePro SP-F AU

Sigen Gateway Home TP AU

Sigen Gateway C60 AU

Phase Type

Single Phase

Single Phase

Three Phase

Three Phase

Nominal AC Voltage

220 / 230 / 240 V

220 / 230 / 240 V

380 / 400 V

380 / 400 V

Max Continuous Power

12 kW

22 kW

30 kW

60 kW

Max Output Current

54.6 A

100 A

45.6 A

91.2 A

Backup Port Output

12 kW @ 0 ms switch¹

22 kW @ 0 ms switch¹

30 kW @ 0 ms switch¹

60 kW @ 0 ms switch¹

Non-Backup Output

Yes

No

Yes

No

Generator Integration

Yes (2-wire start)

Yes (2-wire start)

Yes (2-wire start)

Yes (2-wire start)

Inverter Ports

INV1: 54.6A, INV2: 32A²

INV1: 55A, INV2: 55A, INV3: 32A5

INV1: 45.6A, INV2: 32A⁴

INV1: 45.6A, INV2: 45.6A, INV3: 30A³

Cooling Method

Natural convection

Natural convection

Natural convection

Natural convection

Enclosure Rating

IP55

IP55

IP55

IP55

Dimensions (W × H × D)

450 × 570 × 197 mm

450 × 695 × 177 mm

450 × 695 × 163 mm

510 × 765 × 173 mm

Weight

25 kg

23.5 kg

25 kg

35 kg

Installation Type

Wall-mounted, rear wiring supported

Wall-mounted

Wall-mounted

Wall-mounted

Availability in AU

Available now

Available now

Available now

Available now

 

Sigenergy - Gateway HomePro SP-F Single Phase 22kVA (SigenStor)

  • Works with single phase Sigenergy controllers
  • 100A (22kVA) grid and backup load connections
  • Supports 3 Sigenergy controller connection (maximum 22kVA total)
  • 22kVA smart port connection for backup generator, AC Coupled inverter or smart loads
  • Bottom cable entry only - cable cover included

The new HomePro SP-F gateway is available to order now.

SHOP NOW: Sigenergy - Gateway HomePro

Download Sigenergy Gateway HomePro Data Sheet


Custom Gateway Solutions

For projects that fall outside the standard Sigenergy range, AC Solar Warehouse manufactures custom gateways for both single-phase and three-phase applications. Contact our sales or account management team to arrange a quotation for a custom gateway.

Notes:

1.       0 ms backup switch disruption time achievable when used with Sigen Energy Controller and Sigen Battery.

2.       8 -12 kW inverters should be connected to the INV1 port, 5 - 6 kW inverters should be connected to the INV2 port. The sum of the parallel power of the Sigenergy inverters cannot exceed 12 kW

3.       INV1 and INV2 ports support 17 - 30 kW inverter, the INV3 port supports 5 -15 kW inverter. The sum of the Sigenergy inverters ratings cannot exceed 60 kW. AS4777 does not allow the direct connection of more than two inverters to a gateway that supplies backup loads.

4.       15 - 30 kW inverters should be connected to the INV1 port, 5 -15 kW inverters should be connected to the INV2 port. The sum of the Sigenergy inverters ratings cannot exceed 30 kW.

5.       8.0-12.0 kW inverters should be connected to the INV1 / INV2 port, 3.0-6.0 kW inverters should be connected to the INV3 port. The sum of the Sigenergy inverters ratings cannot exceed 22 kW. AS4777 does not allow the direct connection of more than two inverters to a gateway that supplies backup loads.