Skip to Content
Filters

AC Boards Enphase
AC Board - Enphase IQ System Controller - Pre-Wired Single Phase
Login to see price
AC Board - Enphase IQ System Controller - Pre-Wired Single Phase includes:
- 1x 63A 1P MCB Main (Grid) Switch
- 1x 63A 1P MCB to wire Backup circuits
- 1x 63A 1P MCB to wire Non-Backup circuits
- 1x 40A 1P MCB to series wire 2x IQ Battery 5P's
- 1x 20A 1P MCB to wire 1x IQ Battery 5P
- 3 x 25A 1P MCB to wire 3x single-phase PV circuits
- 1x 16A* 1P MCB wired to the IQ Gateway
- 1x 6A 2P MCB wired as a System Shutdown (SSD) Switch (substitutes the external SSD that the IQ System Controller comes with)
- Enphase battery - Pro plaque label kit
- 6m of communications cable for Enphase batteries
AC Boards Classic
AC Board Classic - 160A Single Inverter
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 160A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Classic
AC Board Classic - 200A Dual Inverter (2 x 100A)
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 800(H) x 600(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 100A Inverter circuit breakers
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

Solar Distribution Boards
AC Board - Breaker Board
Login to see price

This switchboard houses an MCCB with earth and neutral bars, in a GRP (IP66, fire & UV resistant) lockable enclosure.
It can be used as an inverter adjacent isolator (comes with DC system label kit), or even just when a cable size change is required.
It has an internal escutcheon and a fused DIN rail for monitoring equipment, or a GSD for QLD installs, can be added.
Compliant to all relevant standards including AS 61439 with routine verification & QA.

AC Board - SolarEdge Residential DC Combiner Box
Login to see price

DC combiner for residential SolarEdge PV Strings and Batteries
4 fused inputs for up to 4 SolarEdge optimised strings or 10kWh Home Batteries
300 x 230 x 100mm IP65 enclosure
Pre-labelled & wall mounting kit included

AC Boards Classic
AC Board Classic - 200A Single Inverter
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800(H) x 600(W) x 250(D) [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ComAp MainsPro Interface Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

Showing 69 of 69 results