Skip to Content
Filters

Commercial AC Boards

AC Boards Classic
AC Board Classic - 200A Single Inverter
3,995.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800(H) x 600(W) x 250(D) [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 100A Single Inverter
4,071.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 100A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 25kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR Supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 160A Single inverter
4,423.00

Designed for 1 x SolarEdge 82.8kW inverter.


Secondary network protection & solar distribution board includes the following:
- Metal enclosure, 800(H) x 600(W) x 250(D) mm
- Powder-coated steel with top and bottom gland plates
- IP 66 rated for outdoor installation
- 3 point lockable handle
- 160A MCCB main switch
- 148A MCCB inverter circuit breaker
- 160A N/O contactor
- 10A internal GPO
- Spare 3 phase 10A MCB
- ABB secondary network protection relay (preprogrammed to utility requirements)
- Pre-labelled with additional labels included for main switchboard
- All components pre-wired and checked with 2-step QA process
- Suitable for a maximum fault current of 14.5kA
- For higher fault currents, please call ACSW to discuss
- Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

Available modifications:
- ABB network protection relay can be swapped for ComApp MainsPro (+$50)
- Conversion of AC board to slave equivalent without network protection (-$1000)
- Installation of test links for on-site injection testing (+$100)
- Installation of 3P+N AC surge diversion (+$250)
- Installation of General Signalling Device (Queensland only) (+$100)

AC Boards Pro
AC Board Pro - 200A Single Inverter
5,198.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• MainsPro Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR Supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 160A 1-4 Inverters
4,400.00

* Inverter MCB's are not included in this board *
Please advise what inverters are being connected and we can quote these separately.

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800(H) x 600(W) x 250(D) [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 160A
• Mainspro Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 320A Dual Inverter
7,107.00

Designed for 2 x SolarEdge 82.8kW inverters. 


 Secondary network protection & solar distribution board includes the following: 
- Metal enclosure, 1000(H) x 600(W) x 250(D) mm 
- Powder-coated steel with top and bottom gland plates 
- IP 66 rated for outdoor installation 
- 3 point lockable handle 
- 320A MCCB main switch 
- 2 x 148A MCCB inverter circuit breaker 
- 350A N/O contactor 
- 10A internal GPO 
- Spare 3 phase 10A MCB 
- ABB secondary network protection relay (preprogrammed to utility requirements) 
- Pre-labelled with additional labels included for main switchboard 
- All components pre-wired and checked with 2-step QA process 
- Suitable for a maximum fault current of 10kA 
- For higher fault currents, please call ACSW to discuss 
- Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016 


 Available modifications: 
- ABB network protection relay can be swapped for ComApp MainsPro (+$50) 
- Conversion of AC board to slave equivalent without network protection (-$1000) 
- Installation of test links for on-site injection testing (+$100) 
- Installation of 3P+N AC surge diversion (+$250)
- Installation of General Signalling Device (Queensland only) (+$100)

AC Boards Pro
AC Board Pro - 400A Dual Inverter
8,450.00

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 1200(H) x 800(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• 400A main switch
• ComAp MainsPro Grid Protection Relay, pre-programmed to DNSP settings
• Fault current rated to 10kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 x 200A Inverter MCCB's
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

AC Boards Enphase
AC Board Enphase - 160A 1-8 Circuits
9,060.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 1200H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 160A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 14.5kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Power Line Communication phase filtering
• Enphase IQ Gateway and Q-Relay Protection
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)

AC Boards Pro
AC Board Pro - 200A Dual Inverter
5,078.00

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 800(H) x 600(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault current rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 Inverter circuit breakers (100A)
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

AC Boards Classic
AC Board Classic - 100A Single Inverter
3,218.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D
• IP66
• Switchgear rated to 100A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 33.4kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Enphase
AC Board - Enphase IQ System Controller Single Phase (Pre-Wired)
2,308.20

Single Phase Enphase IQ System Controller 3 INT (Pre-Wired) includes:
- 1x 63A 1P MCB Main (Grid) Switch
- 1x 63A 1P MCB to wire Backup circuits
- 1x 63A 1P MCB to wire Non-Backup circuits
- 1x 40A 1P MCB to series wire 2x IQ Battery 5P's
- 1x 20A 1P MCB to wire 1x IQ Battery 5P
- 3 x 25A 1P MCB to wire 3x single-phase PV circuits
- 1x 16A* 1P MCB wired to the IQ Gateway
- 1x 6A 2P MCB wired as a System Shutdown (SSD) Switch (substitutes the external SSD that the IQ System Controller comes with)

This kit also comes with 6m of communications cable for Enphase batteries and the Enphase Pro Plaque Label Kit

AC Boards Classic
AC Board Classic - 160A Single Inverter
3,454.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 160A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Classic
AC Board Classic - 200A Dual Inverter
4,215.00

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 800(H) x 600(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 100A Inverter circuit breakers
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

Commercial AC Boards
AC Board - Sigenergy Gateway Single Phase - 125A Full Backup, 63A Grid Port, 2 x 63A Inverters, 63A Smart Port - Bypass, Surge Diverter
2,106.00

Custom Sigenergy Single Phase Gateway Includes:
- Supports up to 2 x 12kW inverters
- Plastic weatherproof wall mount enclosure: 54P (622H x 448W 161D [mm])
- Prospective fault current: 6kA
- 63A Grid Port MCB (either on-grid or used for the generator while off-grid)
	- 63A AC1 Contactor
	- 1P+N Class 2 Surge Diverter
	- 63A Bypass MCB with auxiliary feedback
- 125A backup load MCB
- 63A smart port / generator MCB
	- 63A AC1 Contactor
- 2 x 63A 6kA MCBs for inverter connections
- Fully pre-wired, labelled and tested to all relevant Australian Standards
	- Installation label kit included

Showing 14 of 14 results