Skip to Content
Filters

AC Boards Pro

AC Boards Pro
AC Board Pro - 100A Single Inverter
4,071.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 100A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 25kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR Supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 160A Single inverter
4,423.00

Designed for 1 x SolarEdge 82.8kW inverter.


Secondary network protection & solar distribution board includes the following:
- Metal enclosure, 800(H) x 600(W) x 250(D) mm
- Powder-coated steel with top and bottom gland plates
- IP 66 rated for outdoor installation
- 3 point lockable handle
- 160A MCCB main switch
- 148A MCCB inverter circuit breaker
- 160A N/O contactor
- 10A internal GPO
- Spare 3 phase 10A MCB
- ABB secondary network protection relay (preprogrammed to utility requirements)
- Pre-labelled with additional labels included for main switchboard
- All components pre-wired and checked with 2-step QA process
- Suitable for a maximum fault current of 14.5kA
- For higher fault currents, please call ACSW to discuss
- Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

Available modifications:
- ABB network protection relay can be swapped for ComApp MainsPro (+$50)
- Conversion of AC board to slave equivalent without network protection (-$1000)
- Installation of test links for on-site injection testing (+$100)
- Installation of 3P+N AC surge diversion (+$250)
- Installation of General Signalling Device (Queensland only) (+$100)

AC Boards Pro
AC Board Pro - 200A Single Inverter
5,198.00

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• MainsPro Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR Supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 160A 1-4 Inverters
4,400.00

* Inverter MCB's are not included in this board *
Please advise what inverters are being connected and we can quote these separately.

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800(H) x 600(W) x 250(D) [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 160A
• Mainspro Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 320A Dual Inverter
7,107.00

Designed for 2 x SolarEdge 82.8kW inverters. 


 Secondary network protection & solar distribution board includes the following: 
- Metal enclosure, 1000(H) x 600(W) x 250(D) mm 
- Powder-coated steel with top and bottom gland plates 
- IP 66 rated for outdoor installation 
- 3 point lockable handle 
- 320A MCCB main switch 
- 2 x 148A MCCB inverter circuit breaker 
- 350A N/O contactor 
- 10A internal GPO 
- Spare 3 phase 10A MCB 
- ABB secondary network protection relay (preprogrammed to utility requirements) 
- Pre-labelled with additional labels included for main switchboard 
- All components pre-wired and checked with 2-step QA process 
- Suitable for a maximum fault current of 10kA 
- For higher fault currents, please call ACSW to discuss 
- Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016 


 Available modifications: 
- ABB network protection relay can be swapped for ComApp MainsPro (+$50) 
- Conversion of AC board to slave equivalent without network protection (-$1000) 
- Installation of test links for on-site injection testing (+$100) 
- Installation of 3P+N AC surge diversion (+$250)
- Installation of General Signalling Device (Queensland only) (+$100)

AC Boards Pro
AC Board Pro - 400A Dual Inverter
8,450.00

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 1200(H) x 800(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• 400A main switch
• ComAp MainsPro Grid Protection Relay, pre-programmed to DNSP settings
• Fault current rated to 10kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 x 200A Inverter MCCB's
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

AC Boards Pro
AC Board Pro - 200A Dual Inverter
5,078.00

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 800(H) x 600(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault current rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 Inverter circuit breakers (100A)
• Spare 3 phase MCB
• Internal RCBO protected GPO
• Separate GPR supply and voltage reference
• Fuse protected monitoring
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

Showing 7 of 7 results