[ZAPPI-2H22UW-T] Myenergi Zappi smart EV charger 7kW/22kW multiphase - Untethered White Myenergi Zappi smart EV charger 7kW22kW multiphase - Untethered White 2.webp Recent price reduction
EV Chargers
Myenergi Zappi smart EV charger 7kW/22kW multiphase - Untethered White
Login to see price

Charging Cable Not Included
Untethered with Type 2 Socket

iStore
iStore 180L heat pump (R290 refrigerant)
Login to see price
Please note that this item is only being drop-shipped from iStore from either MEL, BNE, SYD, ADL, PER.

These items are very large and bulky. Logistics to residential addresses needs to be carefully considered
Heat Pumps
iStore 270L heat pump (R290 refrigerant)
Login to see price

This model contains R290 refrigerant to comply with Victorian standards.

iStore quickie kit 15mm
Login to see price

Includes:
- PTR valve
- Solar Tempering Valve
- 4 Way Tee
- Isolation and Pressure reduction valve
- ECV

Accessories
Under Panel AC Isolator Package (2 x 2 Hole Glands)
Login to see price

An AC Isolator, ready to install directly onto racking. Comes with glands and bootlaces for installation.

AC Boards Classic
AC Board Classic - 100A Single Inverter
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D
• IP66
• Switchgear rated to 100A
• MainsPro Interface Protection Relay, pre-programmed to DNSP settings
• Fault rated to 33.4kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2025, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

AC Boards Enphase
AC Board - Enphase IQ System Controller - Pre-Wired Single Phase
Login to see price
AC Board - Enphase IQ System Controller - Pre-Wired Single Phase includes:
- 1x 63A 1P MCB Main (Grid) Switch
- 1x 63A 1P MCB to wire Backup circuits
- 1x 63A 1P MCB to wire Non-Backup circuits
- 1x 40A 1P MCB to series wire 2x IQ Battery 5P's
- 1x 20A 1P MCB to wire 1x IQ Battery 5P
- 3 x 25A 1P MCB to wire 3x single-phase PV circuits
- 1x 16A* 1P MCB wired to the IQ Gateway
- 1x 6A 2P MCB wired as a System Shutdown (SSD) Switch (substitutes the external SSD that the IQ System Controller comes with)
- Enphase battery - Pro plaque label kit
- 6m of communications cable for Enphase batteries
AC Boards Classic
AC Board Classic - 160A Single Inverter
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800H x 600W x 250D [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 160A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

AC Boards Classic
AC Board Classic - 200A Dual Inverter (2 x 100A)
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Metal Enclosure: 800(H) x 600(W) x 250(D) [mm]
• Enclosure Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ABB Grid Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 2 100A Inverter circuit breakers
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Swap ABB Network Protection Relay for ComApp MainsPro (+$50)
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100->200)
• Install 3P+N AC surge diversion (+$250)

[ACB-CK2R-2B] AC Board - Single Phase Enphase CK2 IQ Battery Retrofit (2 x Circuits) Pre-Order
Residential AC Boards (Enphase)
AC Board - Single Phase Enphase CK2 IQ Battery Retrofit (2 x Circuits)
Login to see price

Includes CK2 and Legrand Plexo enclosure joining kit for retrofitting to existing Enphase AC Board
Contains 2 x 20A MCBs and 2x 1PH Q-Relays for IQ Batteries
Supports up to 4 Flexphase IQ Batteries

AC Board - SolarEdge Residential DC Combiner Box
Login to see price

DC combiner for residential SolarEdge PV Strings and Batteries
4 fused inputs for up to 4 SolarEdge optimised strings or 10kWh Home Batteries
300 x 230 x 100mm IP65 enclosure
Pre-labelled & wall mounting kit included

Commercial AC Boards
AC Board - Polyphase Backup Board
Login to see price
Designed for 3 phase connections and single phase inverters. While off-grid the board will combine all 3 phases into one so the system can act as a 'single phase' system, feeding loads across the original 3 phases.
When the grid comes back up, the board will first un-combine the 3 phases, then reconnect each phase, as a 3 phase system, back to the grid.
The board has adjustable time delays, plenty of wiring space, high quality components and a mechanical interlock to avoid phase faults.
Atmoce Adjustable Battery Levelling Feet Kit (Pack of 4)
Login to see price

Used when floor mounting the Atmoce M-ELV Battery
Kit includes 4 feet, 1 kit required per battery being floor mounted

[ZAPPI-2H22UB-T] Myenergi Zappi smart EV charger 7kW/22kW multiphase - Untethered Black Myenergi Zappi smart EV charger 7kW/22kW multiphase - Untethered Black Recent price reduction
Myenergi
Myenergi Zappi smart EV charger 7kW/22kW multiphase - Untethered Black
Login to see price

Charging Cable Not Included
Untethered with Type 2 Socket

Engineering Services
Schematic Diagram for Solar System >30kVA to 200kVA
Login to see price

Complete electrical schematic detailing equipment specifications, cable sizing, protective device ratings, network interface/export control architecture, and summary schedules for fault levels and voltage rise calculations.

Engineering Services
RPEQ Compliance Report (CR) - Energy Queensland systems over 30kVA up to 200kVA
Login to see price
Post-commissioning RPEQ-certified engineering report validating that the as-built installation, commissioned inverter parameters, and grid protection settings strictly comply with the approved design and Energy Queensland connection agreement.


Engineering Services
Energy Queensland (EQ) Grid Connection & RPEQ Compliance Package
Login to see price
The Energy Queensland (EQ) Grid Connection & RPEQ Compliance Package includes the  SLD, DCR and CR along with all correspondence and fees associated with Energy Queensland for the Grid Connection application.
It also includes the PQ data analysis service (if required). 
Power Quality Meter Rental is also available and sold separately.
AC Boards Classic
AC Board Classic - 200A Single Inverter
Login to see price

Secondary Network Protection and Solar Distribution board includes:
• Board Dimensions: 800(H) x 600(W) x 250(D) [mm]
• Board Colour: RAL 7035
• IP66
• Powder-coated steel with top and bottom gland plates
• Switchgear rated to 200A
• ComAp MainsPro Interface Protection Relay, pre-programmed to DNSP settings
• Fault rated to 18kA
• Fault current applies to entire assembly, complying with AS/NZS 61439.1:10
• For higher fault currents, please call ACSW to discuss
• 3-Point Locking System
• Pre-labelled with additional labels included for MSB
• Pre-wired and factory tested according to AS/NZS 61439.1: Clause 11
• Compliant to AS/NZS 3008.1.1:2017, AS/NZS 3000:2018, AS/NZS 5033:2021, AS/NZS 4777.1:2016, AS/NZS 61439.2:2016

- Available Modifications -
• Install test links for injection testing (+$100)
• Install Generation Signalling Device (Queensland only) (+$100)
• Install 3P+N AC surge diversion (+$250)

Showing 546 of 564 results